Launch offer — valid today only

📄 Digital book in PDF · read it on your phone or print it

Sterile Processing, Illustrated: Every Step and Every Number of the Loop, Always in the Same Order One Topic on Every Page

For the U.S. sterile processing technician exams, CRCST and CBSPD. Decontamination, inspection, packaging, steam, indicators, recalls and sterile storage: every topic gets its own page, first the drawing, then what you need to remember. 67 illustrated pages.

I WANT THE ILLUSTRATED PAGES

🔒 Secure checkout · PDF by email · 30-day guarantee

Every topic, its own pageEach step of the loop drawn, with the explanation right beside it
67 illustrated pages9 parts, from the department map to the final checklist
Up-to-date sourcesAAMI ST79, the CDC disinfection guideline and OSHA
PDF by emailFormat

Look Inside the Book

Every page has one big drawing and a box with the times, temperatures and steps you need to know:

Flexible endoscopes: bedside preclean, leak test before cleaning, every channel, HLD or sterilization, dry.
Flexible endoscopes: bedside preclean, leak test before cleaning, every channel, HLD or sterilization, dry.
Tips, jaws, serrations, box lock, shanks, ratchet, finger rings: drawn and labeled.
Tips, jaws, serrations, box lock, shanks, ratchet, finger rings: drawn and labeled.
Gravity 250 °F/30 min · 270 °F/15 min · Prevacuum 270 °F/4 min · 275 °F/3 min, plus drying.
Gravity 250 °F/30 min · 270 °F/15 min · Prevacuum 270 °F/4 min · 275 °F/3 min, plus drying.
Pouches on edge, basins tilted, trays flat, heavy below, space between.
Pouches on edge, basins tilted, trays flat, heavy below, space between.
ISO 11140-1 Types 1–6: process, specific test, single variable, multi-variable, integrating, emulating.
ISO 11140-1 Types 1–6: process, specific test, single variable, multi-variable, integrating, emulating.
Steam: out of service, notify, retest; EtO/plasma: recall since the last negative BI; 3 empty BI cycles to return.
Steam: out of service, notify, retest; EtO/plasma: recall since the last negative BI; 3 empty BI cycles to return.
Bowie-Dick checks air removal; a BI checks the kill. Different tests.
Bowie-Dick checks air removal; a BI checks the kill. Different tests.
8 steps from point of use to sterile storage, each with its key check.
8 steps from point of use to sterile storage, each with its key check.

Swipe to see more →

These are real pages from the book. The table of contents is the full one: 9 parts and 63 topics.

The Problem Isn't You. It's How It Was Explained to You.

You're at the sterilizer with a tray in your hands, and the lead tech asks which cycle it goes in. Gravity or prevacuum, and for how long? You went over this last night.

In the handbook, the times and temperatures are buried in paragraphs, between exceptions and footnotes. Four numbers with no picture to hang them on just don't stick, least of all after a full shift.

Gravity 250 °F/30 min · 270 °F/15 min · Prevacuum 270 °F/4 min · 275 °F/3 min, plus drying.

In the book, it's one page: gravity on one side, prevacuum on the other. Gravity: 250 °F for 30 minutes or 270 °F for 15. Prevacuum: 270 °F for 4 or 275 °F for 3, with drying shown in its own box.

The same goes for loading the sterilizer, chemical indicator types, the Bowie-Dick test, biological indicators and recalls: each one has its own drawn page.

You look at the page, you see where each number goes, and at the sterilizer you know the standard cycles cold, and you still check the IFU for that tray.

COMPARE FOR YOURSELF

The Same Topic, Two Ways to Study It

THIS
  • The handbook: line after line
  • Instrument parts explained only in words
  • You walk into the exam unsure
The hemostat is a ring-handled, ratcheted clamping instrument whose design comprises several functionally distinct components. Distally, the tips and jaws incorporate transverse or longitudinal serrations intended to secure tissue or vessels without slippage. The jaws articulate at the box lock, a joint which must be inspected for cracks, retained debris and stiffness, and which requires lubrication in accordance with the manufacturer's instructions. Proximally, the shanks transmit closing force to the ratchet mechanism, which should hold securely at each tooth, terminating at the finger rings.
FOR THIS
  • The hemostat in one labeled drawing
  • The parts and checks in a box
  • You see it and you get it
Tips, jaws, serrations, box lock, shanks, ratchet, finger rings: drawn and labeled.
CONTENTS

Take a Look at the 9 Parts and 63 Topics

The department map, microbes and infection prevention, decontamination, instruments, packaging, sterilization methods, monitoring and release, storage and recalls, and exam review: 67 pages, all illustrated.

IThe Department Map · pp. 5-10
  1. One Map: Dirty, Clean, Sterile
  2. Three Zones, Three Air Rules
  3. Traffic Control and Attire
  4. Instructions for Use Come First
  5. The Spaulding Classification
  6. Cleaning, Disinfection, Sterilization: Not the Same
IIMicrobes and Infection Prevention · pp. 11-17
  1. Bioburden: What You Can't See
  2. Biofilm
  3. Hardest to Kill, Ranked
  4. The Chain of Infection
  5. Standard Precautions and Bloodborne Pathogens
  6. PPE On and Off in Order
  7. Prions and High-Risk Tissue
IIIDecontamination · pp. 18-26
  1. Point-of-Use Treatment
  2. Transport: Closed, Labeled, Fast
  3. Sorting at the Sink
  4. Manual Cleaning in 4 Steps
  5. Detergents and pH
  6. The Ultrasonic Cleaner
  7. Washer-Disinfectors: Stages and Loading
  8. Cleaning Verification
  9. Water Quality and Flexible Endoscopes
IVInstruments: Inspect and Assemble · pp. 27-35
  1. Stainless Steel: 300 and 400 Series
  2. Anatomy of a Hemostat
  3. Instrument Families
  4. Inspection Under Magnification
  5. Function Tests: Scissors, Ratchets, Jaws
  6. Insulated and Powered Instruments
  7. Lubrication
  8. Assembling a Set by the Count Sheet
  9. Instrument Tracking and Loaner Sets
VPackaging · pp. 36-41
  1. What Packaging Has to Do
  2. Wrapping: Envelope and Square Folds
  3. Peel Pouches
  4. Rigid Containers
  5. Labeling a Package
  6. Event-Related Sterility
VISterilization Methods · pp. 42-50
  1. How Steam Kills
  2. Gravity vs. Dynamic Air Removal
  3. Times and Temperatures to Know
  4. Loading the Steam Sterilizer
  5. Unloading and Cool-Down
  6. Immediate-Use Steam Sterilization
  7. Ethylene Oxide
  8. Hydrogen Peroxide Gas and Plasma
  9. High-Level Disinfection
VIIMonitoring and Release · pp. 51-57
  1. Three Kinds of Monitoring
  2. Chemical Indicator Types 1 to 6
  3. The Bowie-Dick Test
  4. Biological Indicators
  5. When BIs Run: Routine, Implants, After Repairs
  6. Releasing a Load: Read, Then Release
  7. Documentation That Holds Up
VIIIStorage, Distribution and Recalls · pp. 58-62
  1. Sterile Storage Rules
  2. Handling and Stock Rotation
  3. Case Carts and Distribution
  4. Recalls: First, Second, Third
  5. Quality, Safety and Your Role
IXExam Review and Checklists · pp. 63-67
  1. The Certification Exams at a Glance
  2. Numbers to Know on One Page
  3. Pairs That Get Mixed Up
  4. How to Read an Exam Question
  5. Final Checklist: The Whole Loop

One Page, One Topic, All Clear

Think of it this way:

It's your first week at the assembly table. The count sheet lists the clamps, and you have to check each hemostat before it goes in the tray.

You open the book to the hemostat page and see it drawn and labeled: tips, jaws, serrations, box lock, shanks, ratchet, finger rings, with what to look for on each one.

ISO 11140-1 Types 1–6: process, specific test, single variable, multi-variable, integrating, emulating.

Same with manual cleaning in 4 steps, loading the steam sterilizer, chemical indicator types, the Bowie-Dick test and recalls: each one on its own page.

Sterile Processing Tech Illustrated is 67 illustrated pages in 9 parts, one topic per page, and it ends with exam review pages: the numbers to know, the pairs that get mixed up and a checklist of the whole loop.

What you see drawn, you don't have to memorize.

What's Inside Sterile Processing Tech Illustrated:

Ipp. 5-10

The Department Map

The department as one map, the three zones and their air rules, traffic and attire, IFU first, the Spaulding classification and cleaning vs. disinfection vs. sterilization.

IIpp. 11-17

Microbes and Infection Prevention

Bioburden, biofilm, microbes ranked from hardest to kill, the chain of infection, standard precautions, PPE on and off in order, and prions.

IIIpp. 18-26

Decontamination

Point-of-use treatment, transport, sorting, manual cleaning in 4 steps, detergents and pH, the ultrasonic cleaner, washer-disinfectors, cleaning verification, water quality and flexible endoscopes.

IVpp. 27-35

Instruments: Inspect and Assemble

300 and 400 series steel, the hemostat part by part, instrument families, inspection under magnification, function tests, insulated and powered instruments, lubrication, count sheets, tracking and loaner sets.

Vpp. 36-41

Packaging

What packaging has to do, envelope and square folds, peel pouches, rigid containers, labeling and event-related sterility.

VIpp. 42-50

Sterilization Methods

How steam kills, gravity vs. dynamic air removal, times and temperatures, loading, unloading and cool-down, immediate-use steam sterilization, ethylene oxide, hydrogen peroxide and high-level disinfection.

VIIpp. 51-57

Monitoring and Release

Physical, chemical and biological monitoring, indicator types 1 to 6, the Bowie-Dick test, BIs and when they run, releasing a load and documentation.

VIIIpp. 58-62

Storage, Distribution and Recalls

Sterile storage rules, stock rotation, case carts, recalls step by step, and your role in quality and safety.

IXpp. 63-67

Exam Review and Checklists

The certification exams at a glance, the numbers to know on one page, pairs that get mixed up, how to read a question and the whole-loop checklist.

At the end of the book: Exam review pages: numbers to know on one page, pairs that get mixed up, how to read an exam question and a whole-loop checklist.

Plus: 2 Free Books

Sterile Processing Practice Questions: Exam-Style Q&A

BONUS 1: «Sterile Processing Practice Questions: Exam-Style Q&A»

Value on its own: US$ 17.90

Test yourself topic by topic with exam-style questions and a short explanation for every answer, so you find your weak spots before exam day.

15 Common Sterile Processing Mistakes, Before and After

BONUS 2: «15 Common Sterile Processing Mistakes, Before and After»

Value on its own: US$ 14.90

See the mistakes made most often at the sink, the assembly table and the sterilizer, each one drawn wrong and then right, so you catch them before your lead tech does.

Sterile Processing Tech Illustrated with 2 Free Books

  • Sterile Processing Tech Illustrated: 67 illustrated pagesUS$ 87
  • BONUS 1: Sterile Processing Practice Questions: Exam-Style Q&AUS$ 17.90
  • BONUS 2: 15 Common Sterile Processing Mistakes, Before and AfterUS$ 14.90
  • High-resolution PDF to printIncluded
Total value US$ 119.80
YOUR PRICE:
US$ 37
You save US$ 82.80
YES, I WANT STERILE PROCESSING TECH ILLUSTRATED FOR US$ 37

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.

Secure purchaseEncrypted payment30-day guarantee

PDF by email: We email you Sterile Processing Tech Illustrated as a PDF, together with the two free books. It's a single payment: no installments, no extra charges.

Who This Book Is For

You're in a sterile processing course

You're in a sterile processing course

You see the whole department as one map before the details, and every new topic has its own page to come back to.

Your certification exam is coming up

Your certification exam is coming up

You review part by part, with the numbers to know on one page and the pairs that get mixed up, plus a bonus book of practice questions.

You already work in SPD

You already work in SPD

Print the pages you use most, like loading, indicators and recalls, and keep them handy at the assembly table or the sterilizer.

Everything You Get Today

US$ 119.80US$ 37
YES, I WANT STERILE PROCESSING TECH ILLUSTRATED FOR US$ 37

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.

30DAYS
GUARANTEE

30-Day Guarantee

Try Sterile Processing Tech Illustrated for 30 days, bonus books included.

We refund everything if the file won't open, if the book isn't what you see here, if you were charged twice or if the email doesn't arrive. Just email us.

You pay once. No subscriptions.

Frequently Asked Questions

Is it for me if I already work in SPD and have a certification deadline?

Yes. It follows the topics in the current candidate handbooks for the two US technician exams, CRCST and CBSPD, and it's written for techs already in the department, trainees and people changing careers. It starts with the department map, so it works if you're new, and it goes all the way to monitoring, recalls and exam review.

Where does the content come from?

From ANSI/AAMI ST79, the CDC/HICPAC Guideline for Disinfection and Sterilization, the OSHA Bloodborne Pathogens Standard and the current candidate handbooks for the CRCST and CBSPD technician exams. Device-specific steps are checked against the manufacturer's instructions for use (IFU).

Is it official material?

No. It's an independent illustrated study book. It names the exams and standards only to say what it covers, and it isn't affiliated with or endorsed by any certifying body or organization.

Does it replace my course or on-the-job training?

No. It helps you study and review, but it doesn't replace your training, your facility's policies or the manufacturer's instructions for use. At work, always follow your facility's procedures and the IFU.

Are the practice questions the ones on the exam?

No. The practice questions were written for this book. They follow the exam's topics and style, but they are not official exam questions.

When and how do I get it?

The book and the 2 bonus books come as PDFs by email, sent to the address you enter at checkout.

Do I have to pay every month?

No. It's a one-time payment. No subscription.

Can I have it on paper?

Yes. The PDF is printable: print the whole book or just the pages you want handy at work.

How does the refund work?

You have 30 days. We refund everything if the file won't open, if the book isn't what you see on this page, if you were charged twice or if the email doesn't arrive: just email us.

Before You Close This Page

No more rereading the handbook with nothing sticking.

Sterilizer times and temperatures: you see them drawn and you're set.

You walk into the exam knowing where everything is.

Drawings make studying faster.

The book is right below.

One-time payment: US$ 37 · Guarantee: 30 days · PDF by email

YES, I WANT STERILE PROCESSING TECH ILLUSTRATED FOR US$ 37

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.